| CAPACITANCE
RANGE : |
|
10pf ~ 10μf (100 ~106) |
| CAPACITANCE
TOLERANCE : |
|
NPO: J = ±5% |
|
X7R : K = ±10% , M = ±20% |
|
Z5U : M= ±20% , Z =+ 80% / -20% |
|
Y5V : Z = + 80% / -20% |
| WORKING
VOLTAGE : |
|
E = 25V , F = 50V , G = 63V H = 100V , K = 200V , 501 = 500V
, 102 = 1000V |
| TEMPERATURE
CHARACTERISTICS : |
|
NPO : 0 ± 30ppm / ℃ (-55℃ to + 125℃) |
|
X7R : ±15% △C (-55℃ to +125℃) |
|
Z5U : +22% to -56% △C ( +10℃ to + 85℃) |
|
Y5V : +22% to -82% △C (-30℃ to + 85℃) |
| CAPACITANCE
TEST CONDITIONS : (at 25℃) |
|
NPO : 1.2Vrms max. and 1 MHz. (1 KHz for value above 1000pf) |
|
X7R : 1.0Vrms ± 0.2Vrms and 1KHz. |
|
Z5U : 0.5Vrms ± 0.1Vrms and 1KHz. |
|
Y5V : 1.0Vrms ± 0.2Vrms and 1KHz. |
| DISSIPATION
FACTOR : |
|
NPO : 0.1% max. |
|
X7R : 2.5% max. |
|
Z5U : 4.0% max. |
|
Y5V : 5.0% max. |
|
(All measurement conditions are same as capacitance test at
25℃) |
| DIELECTRIC
STRENGTH : |
|
NPO/X7R/Z5U/Y5V : |
|
0 - 500 VDC
: 250% of rated voltage with 50mA max. charging current. |
|
500 VDC
: 200% of rated voltage with 50mA max. charging current. |
|
1K VDC
: 150% of rated voltage with 50mA max. charging current. |
|
2K- 5K VDC
: 120% of rated voltage with 50mA max. charging current. |
| INSULATION
RESISTANCE : |
|
When measured at 25℃ and rated voltage , the below min. value
will be met : |
|
NPO / X7R : 100K Megeohms or 1000 Megeohm -Microfarads whichever
is less. |
|
Z5U / Y5V : 10K Megeohms or 100 Megeohm - Microfarads whichever
is less. |
| |